XSZ-107BN Series Biological Microscope

XSZ-107BN of bio-microscope has modern frame and can fit 45°inclined monocular, binocular, trinocular head on it. Double layer mechanical stage with adjustable long handle and coaxial coarse/fine focus knob make the operation easily. It is also provided with high quality achromatic objectives, wide field eyepieces and LED lamp adjustable brightness, which guarantee the best image. It is widely used for examination, teaching demonstration, bacteioscopy and cytoscopy in colleges and university, medical and health establishments, research institutes and department of forestry and agriculture and so on.

Specification of Standard Accessories

  1. Objectives
Category Magnification Numerical aperture Working distance
Achromatic Objectives(black or white) 4X 0.10 37.5
10X 0.25 7.316
40X 0.65 0.632
100X(oil) 1.25 0.198
  1. Eyepieces
Designation Magnification Diameter Of The Field Of View Focal Length
Wide Field     10X         18MM   24.94MM
Wide Field   16X(Optional)         11MM   15.58MM
  1. Total magnification
 Objectives Eyepieces Total magnification 4X 10X 40X 100X
10X 40X 100X 400X 1000X
16X (optional) 64X 160X 640X 1600X
  1. Mechanical tube length: 160mm
  2. Objective to primary image distance: 195mm
  3. Stage size: 140mm X 132mm, moving range: 75 X 45mm
  4. ABBE condenser, N.A. =1.25 with iris diaphragm
  5. Coarse/fine focal range: 20mm
  6. Illumination: 3W LED with adjustable brightness
  7. Net weight: 6 kg
  8. Measurement (including viewing head): 262mm(L) X 204mm(W) X 389mm(H)

III.  Structure  (showed as Manual)
XSZ-107 microscope is composed of nine main component parts:

  • Stand: It’s the base bearing total weight of microscope, which built in illumination system, electronic parts and connecting control.
  • Rise and fall support: It connects with stage, arm and condenser. Stage and condenser can move vertically through it for proper operation.
  • Arm: It’s the central part connecting the frame and every main component part. It’s provided with coaxial coarse/fine focus system, with tension adjustable knob and limited stopper. It guarantees the stage rise and down smoothly.
  • Viewing head: It can fit on 45°inclined monocular, binocular, or trinocular head.
  • Eyepieces: Using WF10X or WF16X (optional) wide field eyepiece.
  • Nosepiece: It guarantees comfortable and precise rotation by quadruple revolving nosepiece.
  • Objective: 4X, 10X, 40(S) and 100X(S, Oil) high-quality achromatic objectives make the imaging clearly.
  • Stage: Using double layer mechanical stage, it can be operated much easily by coaxial knob in low position.
  • Condenser: ABBE condenser N.A =1.25 with iris diaphragm.

Operation Instruction

Insert the eyepieces into the eyepiece tube, and screw objectives into the nosepiece in sequence of different magnification from low to high. Then put the specimen on the stage and secure it in the position with tablet and move it to the center of stage.
Turn on the power switch and adjust the brightness from dark to bright slowly. After working, you must adjust the brightness to a little dark before you tune it off.
Observe the specimen from lower magnification objective firstly and move the specimen to the center of view field, then rotate higher magnification objective. You may use the fine focusing knob to obtain the clear image. When 100X (S, Oil) objective is used , you should fill up with cedar wood oil (without bubble ) between the front of objective and the specimen surface. After working, it should be wiped with a few xylene immediately.
In order to obtain bright and clear image, the illumination must be adjusted .When different objective is chosen, you should adjust the iris diaphragm of the condenser and different brightness of the light.
When the lamp needs to replace, you should shut off the power switch and replace it after the lamp is cool. NOTE: The contact must be firmed, and the filament center should be adjusted.

Maintenance

  • * Exam the connection of every component parts is firm when opening the package and installing the microscope. Be careful, not overexert to break the instrument.
  • * Operate correctly, and put the dust cover on the microscope after work to prevent from the dust and oil strain.
  • * Don’t dismantle the instrument rashly besides the replaceable lest the correct position should be breached.
  • * Keep the instrument in dry and cool place and away from the pollution and corrosion.
  • * Please send the instrument to the special repair shop if it goes out of order.
  • * When the objectives and eyepieces won’t be used for a long time, please place them into a dry box , and put the dust cover onto the microscope.

Standard Outfit of XSZ-107BN Biological Microscope:

Objective 4X, 10X, 40(S), 100X(S, Oil)
Eyepiece WF10X
WF16X optional
Viewing Head Sliding Binocular Head
Sliding Trinocular Head optional
Nosepiece Quadruple
Stage Double Layer Mechanical Stage
Illumination 3WLED or 6V / 20W Halogen Lamp
Condenser Abbe Condenser N.A=1.25

 

 VII.  Full Set of the Instrument
Mainframe of bio-microscope of XSZ-107BN             1 PC
Viewing head 1 PC
Objectives: 4X, 10X, 40X(S), 100X(S,O) 1 PC of each
Eyepiece WF 10X                                  1 PAIR
3W LED or 6V/20W halogen lamp                      1 PC
Fuse BGX1-20 (1.0 A)        1 PC
Green filter        1 PC
Ceda wood oil 1 BOTTLE
Operational manual 1 COPY
Power cable 1 PC
Dust cover 1 PC
Desiccant 1 PACKET
Eyepiece WF 16X  OPTIONAL
Plain-concave mirror         OPTIONAL
Yellow & blue filter     OPTIONAL
Wooden box   OPTIONAL

Manual

Manual

Catalog

Catalog